2088 Pressure Transmitter LCD Display Module, Pressure Transmitter LCD Display Head

I. Product Overview:

1. Fully intelligent two-wire 4-20mA operation, 5-digit LCD display.

2. Constant current and constant voltage excitation for sensors: constant current 0.4mA, constant voltage 2.5VDC.

3. ADC input range is ±5mV~±80mV, providing 24-bit core resolution with up to 18 effective bits. The built-in amplification factor of the circuit board is 12~200 times. Supports automatic polarity conversion of sensor signals.

4. Suitable for diffused silicon pressure sensors and ceramic pressure sensors.

5. Provides functions such as main variable zeroing, active and passive migration, 19 unit conversions, 6 display modes, display resolution adjustment, and factory data restoration, catering to the specific needs of various customers.

6. 2~5 point nonlinear correction function to eliminate sensor nonlinear errors.

7. Fully digital calibration with no movable potentiometers, resulting in lower temperature drift.

8. Enhanced anti-interference design, suitable for various industrial environments with harsh electromagnetic conditions.

II. Production and Usage Flowchart:

III. Specifications:

1. Power supply voltage: 12~30VDC, recommended 24VDC. Minimal impact from power supply variations.

2. Signal range: Circuit board range is ±5mV~±80mV, corresponding to a maximum output of 320mV for a 1.5mA diffused silicon sensor.

3. Constant current excitation: 0.4mA, suitable for constant current powered sensors (3~8kΩ).

4. Constant voltage excitation: 2.5VDC/0.5mA, suitable for ceramic piezoresistive sensors.

5. Operating environment: Temperature -30~80°C, humidity <85%, dry and non-corrosive environment.

6. Dimensions: 53*53*23.

7. Load resistance: (VCC-12)/20mA Current output resolution: approximately 1μA.

8. Temperature drift coefficient: <35ppm/°C Display range: -19999~99999.

IV. Product Structure:

(1) External Diagram

(2) Wiring Diagram (Shown for constant current excitation sensor connection)

J3 in the diagram is the calibration communication single-wire interface.

J1 is the sensor terminal block, providing constant voltage and constant current excitation.

24V+ and 24V- are the two-wire transmitter terminals, providing DC24V power and outputting 4~20mA current signal.

V. Selection Guide:

(1) Head Area Description

(3) Full Adjustment Key "S"

Short press in measurement mode to modify display mode.

Long press for 5 seconds in measurement mode to enter full adjustment function (i.e., calibrate transmitter full scale).

In setting mode, it functions as parameter increment by one; long press for continuous shift and increment.

(4) Zero Adjustment Key "Z"

Short press in measurement mode to modify display mode.

Long press for 5 seconds in measurement mode to enter zero adjustment function (i.e., calibrate transmitter zero point).

In setting mode, it functions as parameter shift and decrement by one; long press for continuous shift or decrement.

(5) Key Function Overview

The instrument uses three panel keys to implement all parameter input and calibration data setting and collection. The instrument's setting and input have adopted various optimization measures to improve customer operation speed:

The shift key and increment key have variable rate functions.

The instrument supports both shift and incremental input methods: shift method for menus requiring large number modifications, and incremental method for menus requiring continuous data input.

The instrument stops analog output in setting mode, so if no operation is performed within 60 seconds, it automatically returns to measurement mode.

All set parameters are saved only when exiting the menu normally.

(6) Quick Functions

The instrument has three quick functions: main variable zeroing, active zero migration, and active full scale migration, facilitating quick on-site setup by users.

(7) Main Variable Zeroing

Main variable zeroing, or PV zeroing, refers to the zero point relative to atmospheric pressure, not the zero point of the sensor range. Place the transmitter directly under atmospheric pressure and long press the "M" key for more than 5 seconds to enter the main variable zeroing function. As shown in the right figure, the menu area displays "P=0". Use the "S" and "Z" keys to select the desired operation, and the prompt area displays accordingly:

"NO": Do not perform main variable zeroing;

"YES": Perform main variable zeroing;

"RESET": Restore the zero point before the zeroing operation;

If no key operation is performed within 30 seconds, the instrument returns to measurement mode. This function is prohibited during production and is suitable for field use.

(8) Active Zero Migration

Active zero migration sets the current pressure as the transmitter's zero output. Apply zero pressure to the transmitter and long press the "Z" key for more than 5 seconds. The instrument will alternately display the current pressure value and the zero output current value. As shown in the right figure, the menu area displays "LSt". Use the "S" and "Z" keys to select the desired operation, and the prompt area displays accordingly:

VI. Menu Description:

The instrument menu is divided into three levels: "Production Debugging Menu", "Advanced User Menu", and "General User Menu", distinguished by their respective access passwords.

"Production Debugging Menu"

Access password is "00066", used by the transmitter manufacturer to set basic parameters of the transmitter, determining accuracy, calibration values, etc. Therefore, the production debugging menu is not open to general users to avoid damage to calibration data.

"Advanced User Menu"

Access password is "00016", used for special settings required for field use of the transmitter.

"General User Menu"

Access password is "00001", allows setting of display unit, display resolution, and display mode.

Note: In advanced user and general user menu settings, if no key operation is performed within 60 seconds, it will automatically exit the setting and return to measurement mode.

(1) Password Setting Menu

Loc: Password input menu, settable range (19999~99999), menu prompt "PIN".

Sets the menu access password. If the password is incorrect or no key operation is performed within 30 seconds, it automatically returns to measurement mode.

(2) General User Menu

Unt: User unit setting, settable range (0~18), menu prompt is the set unit.

There are 19 unit settings: "MPa", "KPa", "Pa", "bar", "mbar", "PSI", "mH2O", "mmH2O", "InH2O", "ftH2O", "mHg", "mmHg", "InHg", "Kg/cm2", "atm", "Torr", "m", "cm", "mm".

dot: Display precision setting, settable range (0~4), menu prompt is the current pressure unit.

Display resolution refers to the number of decimal places displayed in measurement mode. Users can set it according to field requirements. More decimal places are not necessarily better; display stability should be prioritized. This menu value is also limited by the transmitter's maximum display value during calibration. If the set number of decimal places exceeds the 5-digit display range when displaying the transmitter's maximum value, the number of decimal places will be limited to ensure the maximum value is displayed correctly.

VII. Product Warranty:

The instrument is warranted for one year from the date of shipment, provided the user complies with the usage and protection rules.

Business Phone
Contact Number 1(029) 8102-8005
Contact Number 2(029) 8113-6005
Business Consultation180 9252 2930
Product Service135 7149 5999
Technical Support139 9190 0175

Industry Category Measurement-Analysis-Instruments
Product Category
Brand: 西仪工控
Spec:
Stock:
Origin: China / Shaanxi / Xianshi
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192